What is a TST BVD applicator?
The Shearwell TST Applicator is designed for use with Tissue Sampling Tags (TSTs). It allows cattle to be tagged, and a tissue sample collected for either BVD or DNA testing simultaneously. The applicator is specifically designed for use with Shearwell Tissue Sampling Tags.
How does a BVD tissue sampling tag work?
A BVD tissue sampling tag uses a metal tissue cutter on the male part of the tag to collect a small tissue sample when the tag is applied to the animal's ear. The sample is retained in the applicator and is then transferred into the sample vial for submission to a laboratory.
How do you use a TST BVD applicator?
Load the male Tissue Sampling Tag into the top jaw of the applicator and the female tag into the bottom jaw. Securely restrain the animal and position the tag correctly in the ear, between the cartilage ribs. Apply firm, steady pressure to close the applicator and collect the tissue sample. The sample tube can then be transferred into the vial supplied for testing.
Where should a BVD tissue sampling tag be placed on a calf?
The tag should be positioned in the centre of the ear, between the cartilage ribs, approximately one-third of the way from the head and two-thirds from the tip of the ear. The male part of the tag should enter from the back of the ear, with the female part at the front. Avoid piercing the cartilage ridges, as this can deform the ear and increase the risk of infection.
Can you tag cattle and take a BVD sample at the same time?
Yes. A Tissue Sampling Tag is designed to collect a tissue sample during the tagging process, so cattle identification and BVD sample collection can be carried out as part of the same procedure.
How should I prepare a TST BVD applicator before tagging?
Before tagging, make sure the tissue cutter is clean and the applicator is correctly loaded. The tags should be positioned so that they do not obstruct your view. The animal should also be securely restrained before the tag is applied.
How do I collect the tissue sample from the TST applicator?
After applying the tag, the tissue sample tube remains in the applicator. Remove the sample vial from its blister pack and place it into the bottom jaw of the applicator. Carefully close the applicator until the vial clicks securely onto the sample tube, then press the thumb catch to release the completed sample.
How should a BVD tissue sample be stored?
Once the vial has been attached and released, check that it is fully sealed and place it in the sample bag. Store the sample in a cool place or refrigerator and do not freeze it. Complete the relevant submission paperwork and send the sample to the laboratory as soon as possible.
What should I do if the BVD sample cannot be collected correctly?
If a suitable tissue sample has not been collected, follow the instructions provided with the relevant Tissue Sampling Tag and your BVD testing programme. Some BVD programmes have specific procedures for repeat sampling, so check the requirements that apply in your region.
Are BVD testing requirements the same across the UK?
No. BVD testing and cattle identification requirements can differ between England, Wales, Scotland and Northern Ireland. Requirements can also change as BVD control programmes develop. For the latest information, see Shearwell's
BVD and Cattle Identification Requirements guide before starting a testing programme.
What tags can I use with the TST BVD applicator?
The TST BVD Applicator is intended for use with Shearwell Tissue Sampling Tags. Shearwell offers TST/BVD tags for cattle, including flag and button options, with tags available for BVD testing and DNA sampling depending on the product selected.